How to get a fire suppression license
Suppression work (clean agent, CO2, foam, dry and wet chemical, and kitchen hood systems) is licensed state by state. Some states license it through the State Fire Marshal, others through a contractor board. Here is the general path, then every state we have verified.
Quick answer
- 20 jurisdictions verified to require a state license, certification or permit for suppression systems
- 9 of them name or accept NICET in the official rule
- 8 list a state exam on the official source
- 3 verified with no statewide license (local rules)
The usual steps
- Find the issuing agency for the state. It is usually the State Fire Marshal or the state contractor board. Each state below links to its page and official source.
- Match your systems to a license class. Several states split engineered systems, pre-engineered systems and kitchen hood systems into separate classes or endorsements.
- Get the qualifying credential. Depending on the state this can be a NICET Special Hazards level, manufacturer training for each system brand, or documented experience.
- Pass the state exam if the state has one.
- Apply with insurance, fees and any company license, then renew on the state's cycle.
- Check the city or county. Local AHJs can require permits, plan review and their own licenses.
State-by-state: verified requirements
| State | Agency | License / certification types | Exam |
|---|---|---|---|
| Alaska | Alaska Dept. of Public Safety – Division of Fire & Life Safety (Life Safety Inspection Bureau) | Special hazard permits IIIA, IIIB, IIIC, IIIC-DO; Class IV for pre-engineered kitchen hood (wet/dry chemical) systems | |
| Arizona | Arizona Registrar of Contractors (ROC) | C-16 Fire Protection Systems (commercial) covers systems using water, steam, gas or chemicals, including restaurant hood protection systems, bottled inert gases and pressurized chemicals; R-16 residential; CR-16 dual | AZ Statutes and Rules Exam (SRE) plus the C-16/R-16 trade exam, each with at least 70% |
| Arkansas | Arkansas Fire Protection Licensing Board (Dept. of Labor & Licensing) | Certificate of Registration (portable/fixed) for fixed fire suppression systems; company licensed only when an employee is licensed for the specific type and brand. | Individual examination for the type of work. Official 20 CAR § 900-301 includes the first exam in the initial individual license fee; an examination retake is $25. |
| Colorado | Colorado Division of Fire Prevention & Control | Fire Suppression System Contractor registration under 8 CCR 1507-11. Official definition: a Fire Suppression System is an assembly of piping, valves, conduits, dispersal openings, sprinkler heads, orifices, or other similar devices that convey extinguishing agents for the purpose of controlling, confining, or extinguishing fire, with the exception of multipurpose residential fire sprinkler systems in one- and two-family dwellings and townhouses that are part of the potable water supply, pre-engineered range hoods, duct systems, and portable fire extinguishers. Any individual or company that employs individuals who physically work on, design, test, inspect, or install any part of a Fire Suppression System must be registered, unless an official exemption applies. Official exemptions include public utilities installing underground supply lines; building owners conducting maintenance under NFPA 25 and filing reports as stated in the rule; an owner installing an NFPA 13D system in his or her own single-family residence when designed by a registered contractor and meeting local requirements; individuals or companies installing pre-engineered range hoods and duct extinguishing systems; and individuals or companies that install, maintain, repair, or test Multipurpose Residential Fire Sprinkler Systems or other systems classified as plumbing under these rules and the Colorado State Board of Plumbers definitions. | |
| Delaware | Delaware State Fire Marshal | Class I certificate (includes special suppression), with a licensed fire suppression company. | |
| Florida | Florida Division of State Fire Marshal (Ch. 633, F.S.) | Fire Protection Contractor III for engineered chemical systems (CO2, foam, dry chemical, Halon/clean agent; excludes pre-engineered systems) under s. 633.318; fire equipment dealer Class D license to service, repair, recharge, hydrotest, install or inspect pre-engineered fire extinguishing systems (s. 633.304). Classes A to C cover portable extinguishers. | Contractor III and dealer exams: 70% to pass (s. 633.318, s. 633.304) |
| Georgia | Georgia Office of Commissioner of Insurance and Safety Fire | Firm licenses and individual technician permits under Ga. Comp. R. & Regs. 120-3-23 for portable fire extinguishers, pre-engineered kitchen or restaurant fire suppression systems, pre-engineered industrial fire suppression systems, and engineered special hazard fire suppression systems. The official OCI fire-suppression professionals page states that the office licenses and permits companies and personnel that install, inspect, recharge, repair, service and/or test portable fire extinguishers or fire suppression systems. | |
| Iowa | Iowa Dept. of Inspections, Appeals & Licensing | Fire protection system contractor license with a Special Hazards Systems Installation endorsement (and, if performing that work, a Special Hazards System Maintenance Inspection endorsement). Official endorsements also include preengineered dry chemical or wet agent systems and preengineered water-based systems in one- and two-family dwellings. Licensed fire protection system technicians work under a licensed contractor. | |
| Louisiana | Louisiana Office of State Fire Marshal | Life Safety Fixed Fire Suppression firm endorsement (includes engineered, pre-engineered, and kitchen suppression) or specialty endorsements for Pre-engineered or Kitchen Suppression, plus licensed personnel. | |
| Massachusetts | Massachusetts Department of Fire Services – Office of the State Fire Marshal (Fire Safety Division Licensing) | Certificate of Competency for each person, by restriction: R47 Engineered Fixed Systems, R48 Pre-Engineered Fixed Systems, R46 Portable Fire Extinguishers, R41 Self-Serve (Motor Fuel) Facilities; plus a Certificate of Registration for each company and each business location (527 CMR 1.00, §1.13.5) | State Fire Marshal written exam for each type of system; you must pre-register by the posted deadline (exams in Stow and Springfield). R41 applicants must first pass the exam and hold R48 |
| Montana | Montana Dept. of Labor & Industry – Fire Protection Licensing | Business license + endorsement for special agent fire suppression systems | |
| Nevada | Nevada State Fire Marshal – Fire Protection Licensing | State Fire Marshal fire protection company license plus individual certificates of registration. Official company class Type E covers fixed fire extinguishing systems, with E-1 for pre-engineered systems and E-2 for other engineered systems. | |
| New Jersey | NJ Dept. of Community Affairs – Division of Fire Safety | Special Hazard Fire Suppression System Contractor; Kitchen Fire Suppression System Contractor | |
| Ohio | Ohio State Fire Marshal (fire protection certification) + Ohio Board of Building Standards (designer certification) | SFM Fire Protection Certification (company and individual): Category 7 engineered and Category 8 pre-engineered fire extinguishing systems other than water, Category 10 aerosol systems. Separately, a BBS Special Hazards Suppression System Designer certification covers system design. | SFM category exam; 70% to pass (Ohio Fire Code 918.4.3) |
| Oregon | Oregon Construction Contractors Board | Construction Contractors Board contractor license with the endorsement that fits the work. Oregon does not issue a separate statewide fire suppression contractor license through the State Fire Marshal. Official CCB: anyone who works for compensation in any construction activity involving improvements to real property must generally be licensed, and most construction and repair services require a license. | The Responsible Managing Individual completes the 16-hour pre-license training and the Oregon contractor exam (80 multiple-choice questions, passing score 70 percent / 56 correct answers, three hours, $60 paid to the exam provider), or follows another official RMI path listed on the CCB license page. |
| Texas | Texas Dept. of Insurance – State Fire Marshal's Office | Company Fire Extinguisher Certificate of Registration (ECR) for planning, certifying, installing or servicing fixed fire extinguisher systems; individual Type PL Planning License, Type A Fixed System License, or Type K Kitchen Cooking Systems License | |
| Utah | Utah State Fire Marshal | Automatic fire suppression concern license: Class H1 (install/modify/service engineered and pre-engineered systems) or H2 (service & maintenance only); individual Certificate of Registration | Open-book written exam (70% to pass); re-exam every 5 years |
| Vermont | Vermont Division of Fire Safety | T2 Chemical Suppression Certificate of Fitness (TQP), required for all individuals who design, install, inspect, service or recharge fixed, non-water fire protection systems. | |
| Virginia | Virginia DPOR – Board for Contractors | FSP (fire suppression contracting – non-water systems) | The firm's designated employee (Class A or B) or qualified individual (Class C) must pass a board-approved examination (18VAC50-22-40, -50, -60) |
| West Virginia | West Virginia State Fire Marshal – Fire Protection Worker licensing | Engineered / Pre-Engineered Fire Suppression System Installer; Engineered / Pre-Engineered Suppression System Technician (maintain/repair only) |
Verified: no statewide license
New Hampshire, Wisconsin, Wyoming. Check the city or county where the job is.
Compare NICET requirements by state, or see the fire suppression license requirements by state table.
Common questions
Is there a national fire suppression license?
No. Licensing for clean agent, CO2, foam, dry chemical and kitchen hood suppression systems is set by each state, and cities and counties can add their own rules.
Which states require a license for suppression systems?
Verified so far (20): Alaska, Arizona, Arkansas, Colorado, Delaware, Florida, Georgia, Iowa, Louisiana, Massachusetts, Montana, Nevada, New Jersey, Ohio, Oregon, Texas, Utah, Vermont, Virginia, West Virginia.
Which states have no statewide suppression license?
Verified so far: New Hampshire, Wisconsin, Wyoming. Check the city or county where the job is.
Do I need NICET for a suppression license?
In 9 of the 20 verified states the official source names a NICET level or accepts NICET (often Special Hazards Suppression Systems). Check each state page for the exact rule.
Are kitchen hood systems licensed separately?
In some states, yes. For example, Texas has a Type K Kitchen Cooking Systems License, Alaska has a Class IV permit for pre-engineered kitchen systems, and New Jersey has a Kitchen Fire Suppression System Contractor permit. See each state page for its official source.